Features

High Frequency IGBT-based Switch-Mode Design

The TS Series utilizes the latest IGBT devices to drive down size and increase performance. The high frequency design delivers fast transient response and low output ripple. This performance coupled with Magna-Power's rugged current-fed power processing, enables confidence in even the most demanding applications.

Fully Programmable Power

All TS Series functions and features of are available and programmable from a variety of control methods, including:

  • Stepless front panel knobs
  • 37-pin isolated analog-digital I/O
  • Computer interface with software and drivers

Various programming interfaces are available, such as LXI TCP/IP Ethernet (+LXI), IEEE-488 GPIB (+GPIB), Edgeport USB, Accessory (+USB), RS485 Accessory (+RS485).

Broad Voltage-Current Range, Consistent Controls

Magna-Power Electronics TS Series provides a wide voltage and current range while still maintaining among the highest power density rack-mount packaging. The TS Series IV covers voltages from 5 Vdc up to 4000 Vdc (floating) and current levels from 1.2 Adc up to 2700 Adc. Models 5 kW to 15 kW are available in a 3U chassis, models 20 kW to 30 kW are available in a 6U chassis, and 45 kW models are available in a 9U chassis.

Designed for Safety

TS Series power supplies have extensive diagnostic functions, including: phase loss, excessive thermal conditions, over voltage trip (programmable), over current trip (programmable), cleared fuse, and excessive program line voltage. When in standby or diagnostic fault, the AC mains are mechanically disconnected via an embedded AC contactor, providing confidence that the unit is only processing power when desired.

Scalable Master-Slave Operation

For maximum flexibility, all TS Series power supplies can be scaled a in master-slave configuration for higher voltage or current output. Using the plug and play Universal Interface Device (+UID47), units are tied together in via their 37-pin I/O, allowing an increase in system current when configured in parallel or increase in system voltage when configured in series—up to the power supply's output isolation rating.

Extensive Programming Support and Included Software

All TS Series power supplies come standard with a National Instruments LabVIEW and LabWindowsâ„¢/CVI drivers. In addition, an IVI driver is included supporting Visual C++, Visual C#, Visual Basic .NET, MATLAB, Measure Foundry, PAWS, Visual Basic 6.0, and Agilent VEE Pro. A Standard Commands for Programmable Instrumentation (SCPI) command set is also supported, allowing programming using raw ASCII commands. Finally, Magna-Power's RIS Panel software is provided allowing for a virtual control panel controlling the power supply via any of the available communication interfaces.

Models

There are hundreds of possible configurations for the TS Series product. Using the following ordering guide and models chart to define the best model for your application. Need less power? Visit our XR Series product line. Need more power? Visit our MS Series product line.

Model Ordering Guide

Models Chart

The following chart details the available standard TS Series models. The Current Maximum (Adc) column is separated by the available power levels. To determine the appropriate model, first select your output Voltage Maximum (Vdc) to find appropriate row. Next, select one desired Current Maximum from the row that contains your desired Voltage Maximum. Then, construct your model number according to the model ordering guide, above. Non-standard voltage and current configurations are available.

  5 kW 10 kW 15 kW 20 kW 25 kW 30 kW 45 kW    
Voltage Maximum Current Maximum Ripple (mVrms) Eff. (%)
5 900 1800* 2700* N/A N/A N/A N/A 50 86
8 600 1200* N/A N/A N/A N/A N/A 40 86
10 500 900 1800* N/A 2700* N/A N/A 40 86
16 300 600 900 1200 1500 1800 2700 35 86
20 250 500 750 1000 1250 1500 2250 40 86
25 200 400 600 800 1000 1200 1800 40 86
32 150 300 450 600 750 900 1350 40 86
40 125 250 375 500 625 750 1125 40 87
50 100 200 300 400 500 600 900 50 87
60 83 166 249 332 415 498 747 60 87
80 62 124 186 248 310 372 558 60 87
100 50 100 150 200 250 300 450 60 87
125 40 80 120 160 200 240 360 100 87
160 31 62 93 124 155 186 279 120 87
200 25 50 75 100 125 150 225 125 87
250 20 40 60 80 100 120 180 130 88
300 16 32 48 64 80 96 144 160 88
375 13 26 39 52 65 78 117 170 88
400 12 24 36 48 60 72 108 180 88
500 10 20 30 40 50 60 90 220 88
600 8 16 24 32 40 48 72 250 88
800 6 12 18 24 30 36 54 300 88
1000 5 10 15 20 25 30 45 350 88
1250 4 8 12 16 20 24 36 375 88
1500 3.3 6.6 9.9 13.2 16.5 19.8 29.7 400 88
2000 2.5 5.0 7.5 10.0 12.5 15.0 22.5 450 88
3000 1.6 3.2 4.8 6.4 8.0 9.6 14.4 500 88
4000 1.2 2.4 3.6 4.8 6.0 7.2 10.8 550 88
  Input Current Per Phase (Aac)    
208/240 Vac, 1Φ 38 N/A N/A N/A N/A N/A N/A    
208/240 Vac, 3Φ 19 36 54 72 90 108 162    
380/415 Vac, 3Φ 10 21 30 40 50 60 90    
440/480 Vac, 3Φ 9 18 27 36 45 54 81    

For models with the High Slew Rate Output Option (+HS), ripple will be higher. Models marked with an asterisk (*) are special low-voltage high-current models that may vary in size and input current from the standard TS Series models in the same power envelope. Contact your local sales partner for additional details.

Specifications

Input
Nominal Voltage
3 phase, 3 wire + ground
208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
380 VAC (operating range 342 - 440 VAC)
415 VAC (operating range 373 - 456 VAC)
440 VAC (operating range 396 - 484 VAC)
480 VAC (operating range 432 - 528 VAC)
1 phase, 2 wire + ground
(5 kW models only)
208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
Frequency 50 through 400 Hz (operating range 45 Hz to 440 Hz)
Power Factor Greater than 92% at maximum power for 3 phase models,
Greater than 70% at maximum power for 1 phase models.
Output Specifications
Ripple See Model Charts
Line Regulation Voltage Mode: ± 0.004% of full scale
Current Mode: ± 0.02% of full scale
Load Regulation Voltage Mode: ± 0.01% of full scale
Current Mode: ± 0.04% of full scale
Load Transient Response 2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change
Efficiency ≥ 86% (See Model Charts)
Stability ± 0.10% for 8 hrs. after 30 min. warmup
Isolation User inputs and outputs: referenced to earth ground.
Maximum input voltage to ground: ±2500 Vac
Maximum output voltage to ground:
±1000 Vdc for models less than or equal to 1000 Vdc,
±(2000 Vdc + Vo/2) for models greater than 1000 Vdc or with High Isolation Output Option (+ISO) where Vo is the maximum output voltage of the power supply.
Maximum Slew Rate Standard Models:
100 ms for an output voltage change from 0 to 63%,
100 ms for an output current change from 0 to 63%.
With High Slew Rate Option (+HS):
4 ms for an output voltage change from 0 to 63%,
8 ms for an output current change from 0 to 63%.
Bandwidth Standard Models:
3 Hz with remote analog voltage programming,
2 Hz with remote analog current programming.
With High Slew Rate Option (+HS):
60 Hz with remote analog voltage programming,
45 Hz with remote analog current programming.
Physical Specifications
Power Size (H" x D" x W") Rack Units Weight
5 kW 5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm) 3U 74 lbs (34.57 kg)
10 kW 5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm) 3U 94 lbs (42.64 kg))
15 kW 5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm) 3U 125 lbs (56.70 kg)
20 kW 10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm) 6U 195 lbs (88.45 kg)
25 kW 10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm) 6U 220 lbs (99.79 kg)
30 kW 10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm) 6U 245 lbs (111.13 kg)
45 kW 15¾" x 24" x 19" (40.01 x 60.96 x 48.26 cm) 9U 365 lbs (165.56 kg)
Control Specifications
Voltage Programming Accuracy ± 0.075% of full scale voltage
OVT Programming Accuracy ± 0.075% of full scale voltage
Current Programming Accuracy ± 0.075% of full scale current
OCT Programming Accuracy ± 0.075% of full scale current
Voltage Readback Accuracy ± 0.2% of full scale voltage
Current Readback Accuracy ± 0.2% of full scale current
External Analog Programming and Monitoring Levels 0 - 10 Vdc
External Analog Output Impedances Voltage output monitoring: 100 Ω
Current output monitoring: 100 Ω
+10 Vdc reference: 1 Ω
External Digital Programming and Monitoring Limits Input: 0 to 5 Vdc, 10 kΩ input impedance
Output: 0 to 5 Vdc, 5 mA drive capacity
Remote Sense Limits 3% maximum voltage drop from output to load
Environmental
Operating Temperature 0°C to 50°C
Storage Temperature -25°C to +85°C
Ambient Temperature 0 to 50°C
Temperature Coefficient 0.04%/°C of maximum output voltage,
0.06%/°C of maximum output current.
Air Cooling (Standard) Side air inlet, rear exhaust
Water Cooling (Optional) 25°C maximum inlet temperature
1.5 GPM minimum flow rate for 15 kW units
3.0 GPM minimum flow rate for 20-30 kW units
4.5 GPM minimum flow rate for 45 kW units
80 PSI maximum pressure
1/4” NPT female pipe size

Diagrams

For maximum flexibility, all front panel function and controls have equivalent programming and monitoring functions on the included rear 37-pin analog-digital I/O connector and on the computer programming interface.

A Version Front Panel (TSA)

The A Version front panel provides a digital display with rotary front panel input, isolated 37-pin analog-digital I/O, and a RS232 computer interface.

D Version Front Panel (TSD)

In addition to the features of the A Version front panel, the D Version front panel provides digital 10-key entry, auto-sequencing with memory capability, and modulation for non-linear power profile emulation.

C Version Front Panel (TSC)

The C Version front panel is blank, providing only a switch to enable control power. All control must be performed by the provided isolated 37-pin analog-digital I/O or through a computer interface.

A
  • Engages and disengages main power
B
Meters display output voltage, output current, voltage set point, current set point, over voltage trip, and over current trip
C
Over voltage trip and over current trip setting potentiometers
D
Mode
  • POWER: Indicates power output
  • STANDBY: Indicates control power only
E
Configuration
  • REM SEN: Remote sense enabled
  • INT CTL: Front panel start/stop/clear enabled
  • EXT CTL: External start/stop/clear enabled
  • ROTARY: Front panel rotary knob input
  • KEYPAD: 10-digit numeric keypad control
  • EXT PGM: External analog voltage-current control
  • REMOTE: Computer control
F
Diagnostic Alarms
  • LOCK: Interlock
  • PGM LN: External input voltage beyond limits
  • OVT: Over voltage protection has tripped
  • OCT: Over current protection has tripped
  • THERM: Over temperature condition
  • PHASE: Under voltage AC input
  • FSE: Warns that a fuse has cleared
  • ARM: Indicates power supply is ready for or operating in auto-sequencing
G
Power switch energizes control circuits without engaging main power Diagnostic Alarms
H
Stepless rotary knob to set voltage-current
I
Function Keys
  • MENU: Selects function
  • ITEM: Selects item within function
  • V/I DIS: Displays voltage-current settings
  • TRIP DIS: Displays OVT and OCT setting
  • CLEAR: Clears settings or resets fault
  • ENTER: Select item
J
Memory location indicator, used for auto-sequencing applications
K
Digital input keypad

Front Panel Dimensions

Front panel dimensions diagram references to a, b and c correspond to values in following table:

Power a b c
5 kW 2.250" N/A 5.219"
10 kW 2.250" N/A 5.219"
15 kW 2.250" N/A 5.219"
20 kW 3.000" 2.250" 10.469"
25 kW 3.000" 2.250" 10.469"
30 kW 3.000" 2.250" 10.469"
45 kW 4.750" 4.000" 15.719"

Rear Panel Dimensions (3U) (Standard, Air Cooled)

Rear Panel Dimensions (3U) (Optional, Water Cooled +WC)

Rear Panel Dimensions (6U/9U) (Standard, Air Cooled)

Rear Panel Dimensions (6U/9U) (Optional, Water Cooled +WC)

Side Panel Dimensions (3U) (Standard, Air Cooled)

Side Panel Dimensions (6U/9U) (Standard, Air Cooled)

1
Front Panel Handles
2
Rear Air Exhaust
3
  • Output DC Connections - 3/8-16 Threaded Insert>
  • Qty (1) Insert Per Bus Bar, 5 kW to 15 kW Models
  • Qty (2) Inserts Per Bus Bar, 20 kW to 30 kW Models
  • Qty (4) Inserts Per Bus Bar, 45 kW Models
4
Computer and External Control Connections
5
Remote Sensing Connector
6
Input AC Connections
1/4-20 Bolt, Qty (4) PLC’S
7
Front Panel Handles
8
Side Air Intake (Air-Cooled Models Only)
9
Output DC Connections, 5 kW - 15 kW (Side View)
10
Output DC Connections, 20 kW - 45 kW (Side View)

Note: Metal Cover included for rear panel on 5 kW to 15 kW models. Stand-offs included for all other models.

Options

The following options are available for the TS Series programmable DC power supply:

CAB1, CAB2, CAB3, CAB4, CAB3x2, CAB4x2

Cabinet and Integration

Installation of Magna-Power products into reliable Premier Metal or Hoffman® cabinet, equipped with casters, fixed rails, and cabinet fans integrated with products control circuitry.


More

CBL

DC Power Cabling, Terminated

Utilizing Magna-Power's internal cable manufacturing operations, custom-made DC power cables are offered as an accessory. 


More

+ISO

High Isolation Output
Available for models rated for 250 Vdc to 1000 Vdc, the +ISO option extends the output isolation, used when the application demands floating or tying units in series beyond the standard 1000 Vdc output isolation rating.
More

+HS

High Slew Rate Output
The high slew rate option is a control modification and replaces the standard output stage with one of low capacitance film and/or aluminum electrolytic capacitors, capable of high RMS currents. This stage provides higher bandwidth with faster output rise and fall times.
More

+GPIB

IEEE-488 GPIB Interface
Full control of the product's features and diagnostics over a IEEE-488 GPIB interface. The GPIB interface allows up to 15 devices may be connected to one bus and is compatible with all Magna-Power provided software and drivers.
More

+LXI

LXI TCP/IP Ethernet Interface
Full control of all the product's features and diagnostics over a LXI Class C Certified TCP/IP Ethernet interface. Includes an embedded web server and compatibility with all Magna-Power provided software and drivers.
More

RS485

RS-422 or RS-485 Converter (Accessory)

The RS-232 to RS422 or RS-485 converter is an external industrial accessory to convert the power supply's standard RS-232. Unlike converters which require programming hardware handshaking signals to control RS-485 or RS-422 operation, the +RS485 option provides automatic control.


More

UID47

Universal Interface Device (Accessory)

The UID47 accessory eases master-slave parallel or series configuration of Magna-Power DC power supplies, enabling near equal current or voltage sharing, depending on the configuration. The accessory includes the UID47 with integrated circuitry and (2) 6-ft DB37 cables.


More

USB

USB Edgeport Converter (Accessory)

The +USB Edgeport Converter plugs directly into the product's RS232 port, creating a virtual serial COM port over USB. The converter is tested with the product by Magna-Power at time of production.


More

+WC

Water Cooling
Water cooling is available instead of the standard air cooling. Water cooled units are fully enclosed and to not take in any external air, making them ideal for corrosive environments, densely packed cabinets or setups where water is readily available.
More

How to Buy

For the fastest product and pricing information, please complete the form and the Magna-Power team will address the request immediately.

Build-time

Magna-Power products are made-to-order with build-times that vary depending on the model's maximum power rating. Current build-time schedules are as follows:

Models 5 kW-15 kW, ≤ 1000 Vdc

4 weeks

All Models 20 kW-45 kW
All Models > 1000 Vdc

5.5 weeks

Sales Partners

In the USA and Canada, Magna-Power sells it products directly from the factory, with a nationwide network of technical representatives. Magna-Power products are available available worldwide through direct sales offices and authorized distributors. Requests from this form will either be quoted directly or automatically routed to the appropriate sales partner for quote.

Prefer to Talk?

Feel free use the Live Chat or give us a call: +1 (908) 237-2200

Please use the following form to request a MagnaDC price and lead-time quote. During business hours, quotes are generally emailed within 1 hour. Required Field*

 

MagnaDC Requirement

Check the Box Below